Face Fit Testing – Qualitative & Quantitative On-Site Testing
Professional Face Fit Testing at Your Workplace
Does your team wear tight-fitting respiratory protective equipment (RPE) to protect themselves from hazardous dust, fumes, vapours or airborne contaminants?
Ensuring respiratory protection fits correctly is essential.
Even a small gap between the mask and the wearer's face can allow contaminated air to enter, reducing the protection the equipment is designed to provide.
At Emergency Response Training Ltd, we offer professional on-site Face Fit Testing for businesses and organisations across Yorkshire and surrounding counties, with nationwide delivery available on request.
We provide both qualitative and quantitative Face Fit Testing, helping employers establish whether their employees' chosen tight-fitting respirators provide an adequate facial seal.
Our testing is carried out at your premises, reducing travel time and disruption to your working day.
Testing methods: Qualitative and Quantitative
Delivery: On-site at your workplace
Suitable for: Disposable half masks, reusable half masks and full-face respirators, depending on the testing method
Availability: By appointment
Pricing: Contact us for a quotation
What Is Face Fit Testing?
Face Fit Testing is a procedure used to establish whether a particular make, model and size of tight-fitting respirator provides an adequate seal against an individual's face.
Everyone's facial features are different. A respirator that fits one employee correctly may not fit another.
A successful fit test helps establish whether the selected respirator is suitable for the individual wearer.
Face Fit Testing is different from a user seal check, which should be carried out each time a tight-fitting respirator is put on.
Where tight-fitting RPE is required, employers should ensure that the selected equipment is suitable for the wearer and that an appropriate fit test has been completed.
Who Needs Face Fit Testing?
Face Fit Testing is required where workers need to wear tight-fitting respiratory protective equipment as part of their protection against workplace respiratory hazards.
This may include employees working in:
-
Construction and demolition
-
Manufacturing and engineering
-
Woodworking and joinery
-
Welding and metal fabrication
-
Painting and surface preparation
-
Waste management and recycling
-
Agriculture and horticulture
-
Industrial cleaning
-
Maintenance and refurbishment
-
Healthcare and laboratory environments
-
Asbestos-related work
-
Other environments where tight-fitting RPE is required
The type of respiratory protection required should be determined through the employer's risk assessment, taking account of the substances involved, exposure levels and working conditions.
Our Face Fit Testing Methods
We offer two methods of Face Fit Testing, depending on the type of respiratory protective equipment being worn.
Face fit testing partnership | RPE | uvex safety
Qualitative Face Fit Testing
A taste-based method using a hood and bitter or sweet test solutions. Suitable for compatible tight-fitting disposable and reusable half-mask respirators.
Respirator Fit Testing | Power Generation & Mining
Quantitative Face Fit Testing
An instrument-based method using specialist particle-counting equipment to measure respirator leakage. Suitable for tight-fitting disposable half masks, reusable half masks and full-face respirators.
Qualitative Face Fit Testing – Taste Method
Qualitative Face Fit Testing is commonly known as the hood or taste test.
This method uses a specialist hood and either a bitter or sweet-tasting solution to determine whether the wearer can detect leakage into their respirator.
It is suitable for compatible tight-fitting disposable half masks and reusable half-mask respirators.
How Does Qualitative Face Fit Testing Work?
Step 1 – Sensitivity Test
Before the main fit test, the candidate completes a sensitivity test to establish whether they can detect the test solution.
A weaker bitter or sweet solution is introduced into the hood.
If the candidate cannot detect the first solution within the prescribed sensitivity test procedure, the alternative solution may be considered.
If neither solution can be detected, quantitative testing may be recommended instead.
Step 2 – Fitting the Respirator
The candidate puts on their selected respirator, ensuring it is positioned and adjusted correctly.
Other head-worn personal protective equipment, such as safety spectacles, helmets or hearing protection, should also be considered where these are normally worn during work.
Step 3 – The Fit Test
The hood is positioned over the candidate's head and the main test solution is introduced.
The wearer completes a series of prescribed exercises designed to simulate movements that may occur during normal working activities.
The test checks whether the wearer can detect the solution while carrying out these movements.
Step 4 – Test Result
If the candidate does not detect the solution during the prescribed exercises, and the test procedure is completed successfully, the respirator may achieve a pass.
If the solution is tasted during the test, this indicates that the selected respirator has not achieved an adequate fit under the test conditions.
A different size, make or model may be required before retesting.
Quantitative Face Fit Testing – Particle Counting Method
Quantitative Face Fit Testing uses specialist equipment, such as a PortaCount, to measure the effectiveness of the seal between a respirator and the wearer's face.
Unlike qualitative testing, the method does not depend on the candidate being able to taste a solution.
Instead, the equipment measures particle concentrations inside and outside the respirator and calculates a numerical fit factor.
Quantitative testing can be used for compatible:
-
Disposable tight-fitting half-mask respirators
-
Reusable half-mask respirators
-
Full-face respirators
How Does Quantitative Face Fit Testing Work?
Step 1 – Preparing the Test Environment
The testing equipment is set up in a suitable room.
The method uses airborne particles, either naturally present or supplemented using an appropriate particle generator.
Suitable particle levels must be maintained throughout the test.
Step 2 – Fitting the Respirator
The candidate puts on their selected respirator and any other head-worn PPE normally used during their work.
The respirator is connected to the testing equipment using the appropriate sampling arrangement.
Step 3 – Completing the Test Exercises
The candidate completes the prescribed test exercises while the equipment measures particle concentrations inside and outside the respirator.
Depending on the applicable testing protocol, the exercises may include movements and activities intended to challenge the respirator seal.
Step 4 – Measuring the Fit Factor
The equipment calculates a fit factor, providing an objective numerical measurement of the respirator's performance during the test.
The result is compared against the required pass level for the respirator and test protocol.
If the candidate fails, adjustments or an alternative respirator may be considered before further testing.
Qualitative vs Quantitative Face Fit Testing
Qualitative Testing Quantitative Testing
Taste-based testing Instrument-based testing
Uses a specialist hood Uses particle-counting equipment
Bitter or sweet solution Measures particle concentrations
Pass/fail based on detecting the solution Numerical fit factor
Compatible half-mask respirators Compatible half-mask and full-face respirators
Candidate must detect the solution Does not rely on taste sensitivity
Both methods are established approaches to respiratory fit testing when used for appropriate respirators and carried out in accordance with the relevant procedures.
Preparing for Your Face Fit Test
To help ensure testing can be completed successfully, employees should arrive prepared.
Clean-Shaven Requirement
Employees must be clean-shaven wherever the tight-fitting respirator seals against the face.
Facial hair, including stubble, beards and moustaches that cross the sealing area, can prevent an adequate seal and compromise respiratory protection.
Where an employee cannot be clean-shaven, a suitable alternative such as a powered loose-fitting hood or helmet may be considered, subject to the employer's respiratory protection assessment.
Eating, Drinking and Smoking
Before testing, candidates should follow the preparation instructions provided with their appointment.
For qualitative testing, candidates should avoid eating, drinking anything other than water, smoking or vaping for at least 30 minutes before the test.
For quantitative testing, our preparation instructions may require a longer period, depending on the equipment and testing protocol.
Bring Your Respiratory Protection
Candidates should have the exact make, model and size of respirator they normally use at work, together with any other head-worn PPE that may affect the fit.
This helps ensure testing reflects their actual working conditions.
Why Is Face Fit Testing Important?
Respiratory protective equipment is only effective when it is correctly selected, worn and maintained.
A respirator may appear to fit comfortably but still allow contaminated air to enter through gaps around the face seal.
Face Fit Testing helps employers:
-
Identify suitable tight-fitting respirators for individual employees
-
Reduce the risk of leakage around the face seal
-
Support compliance with workplace respiratory protection requirements
-
Improve employee awareness of correct respirator fitting
-
Identify where a different size or model may be needed
-
Maintain appropriate respiratory protection arrangements
A successful fit test applies to the specific make, model and size of respirator tested. It should not be assumed that other respirators will provide the same fit.
When Should Face Fit Testing Be Repeated?
Face Fit Testing should be considered when:
-
A worker is first provided with tight-fitting RPE
-
The make, model or size of respirator changes
-
Significant facial changes may affect the seal
-
Dental work, surgery or substantial weight changes affect facial fit
-
Concerns arise about the respirator's fit
-
The employer's RPE assessment or applicable requirements indicate that further testing is necessary
Employees should also carry out an appropriate user seal check whenever they put on their tight-fitting respirator.
On-Site Face Fit Testing at Your Workplace
We provide Face Fit Testing at customers' premises, allowing employers to arrange testing for their teams without sending employees to an external training centre.
On-site delivery is particularly useful for construction companies, manufacturing businesses, engineering firms, industrial organisations and employers with multiple respirator wearers.
We can discuss the number of employees requiring testing, the types of respirators being used and whether qualitative or quantitative testing is appropriate.
[Contact Us for Availability and Pricing]
Face Fit Testing Across Yorkshire and Surrounding Areas
Emergency Response Training Ltd is based in Doncaster and provides on-site Face Fit Testing across South Yorkshire and surrounding regions.
Our service areas include:
South Yorkshire: Doncaster, Sheffield, Rotherham, Barnsley and surrounding areas.
West Yorkshire: Leeds, Wakefield and surrounding areas.
North Yorkshire: York and surrounding areas.
Nottinghamshire: Worksop, Retford, Nottingham and surrounding areas.
Derbyshire: Chesterfield and surrounding areas.
Lincolnshire: Scunthorpe, Gainsborough, Lincoln and surrounding areas.
East Yorkshire and the Humber: Hull and surrounding areas.
We can also discuss nationwide testing requirements for businesses operating across multiple locations.
Why Choose Emergency Response Training?
Established in 2002, Emergency Response Training Ltd provides workplace training and safety services to organisations across Yorkshire and beyond.
Our customers benefit from:
-
A Doncaster-based business with over 24 years' experience
-
On-site delivery at customer premises
-
Qualitative and quantitative testing options
-
Flexible appointments for businesses
-
Support for employers with multiple respirator wearers
-
A friendly and professional team
-
Additional workplace health and safety training services
We understand the importance of arranging workplace safety services around operational requirements and aim to make the booking process straightforward.
Book On-Site Face Fit Testing
Whether you need testing for a small team or a larger group of employees, contact us to discuss your requirements.
To provide an accurate quotation, it is helpful to know the number of employees requiring testing, the types of respirators being used and the location of your premises.
Emergency Response Training Ltd
Telephone: 01302 802016
Email: mail@ertraining.co.uk
Contact Us: HERE
3. Frequently Asked Questions
What is Face Fit Testing?
Face Fit Testing checks whether a particular tight-fitting respirator provides an adequate seal against an individual's face. It helps identify whether the selected make, model and size is suitable for the wearer.
Is Face Fit Testing a legal requirement?
Where tight-fitting RPE is required to control exposure to hazardous substances, appropriate fit testing is necessary to demonstrate that the respirator fits the wearer adequately. Employers should follow relevant HSE guidance and applicable workplace safety regulations.
What is the difference between qualitative and quantitative Face Fit Testing?
Qualitative testing uses a bitter or sweet solution to detect leakage through the respirator seal. Quantitative testing uses specialist equipment to measure leakage and calculate a numerical fit factor.
Can disposable FFP3 masks be Face Fit Tested?
Yes. Suitable disposable tight-fitting FFP3 respirators can be tested using an appropriate qualitative or quantitative method.
Can full-face respirators be tested?
Yes. Full-face respirators can be tested using an appropriate quantitative method. Qualitative taste testing is not suitable for full-face respirators.
Do employees need to be clean-shaven?
Yes. Employees must be clean-shaven in the area where the respirator seals against the face. Facial hair crossing the sealing surface can prevent an effective fit.
What happens if someone fails a Face Fit Test?
A different size, make or model of respirator may be required. The wearer can be retested once the relevant preparation and testing requirements have been met.
Can employees wear safety glasses or helmets during testing?
Yes. Other head-worn PPE normally used at work should be considered during testing because it may interfere with the respirator seal.
How long does Face Fit Testing take?
The time required depends on the testing method, respirator type, number of employees and whether any retesting is necessary. Contact us to discuss your requirements.
Do you offer Face Fit Testing at our workplace?
Yes. We provide on-site qualitative and quantitative Face Fit Testing at customer premises across Yorkshire and surrounding areas, with nationwide delivery available on request.
Whilst you are here, why not check out what other Health & Safety Services we offer:
-
Health & Safety Risk Assessments
-
Fire Risk Assessment & Consultancy
